Magnetism and electromagnetism simulation

Transformers and National Grid Simulation

A glowing iron-cored transformer with copper coils, a lamp and a live trace, plus a National Grid landscape with a power station, pylons and a small town. Set the turns, swap the coils, try d.c., then raise the transmission voltage and watch the current and the heating loss fall.

Loading simulation…
Show symbols for

Predict first

Question 1 of 4

A transformer has 1000 turns on its primary coil and 50 turns on its secondary coil. The primary is connected to a 230 V a.c. supply. What is the output voltage (p.d.) across the secondary coil?

Try this

  1. 1Keep the starting set-up (230 V across 1000 turns, 50 turns on the secondary, a 5 Ω lamp). Work out 230 × 50 ÷ 1000 and compare it with the Output voltage card. Then compare the Output current with the Input current: which is bigger, and how many times bigger?
  2. 2Choose 12 V up to 48 V from the Examples menu, note both currents, then press Swap. The transformer now steps down: how many times smaller is the output than the input, and what has happened to the current in the lamp?
  3. 3Press Use d.c., press Play and watch the trace and the lamp. Then press Off and On a few times. At which moments is anything induced in the secondary coil, and why only then?
  4. 4Press Grid. The power station sends 100 MW at 25 kV with no step-up. Note the Current in the lines and Heating the lines cards, then press Raise three times to reach 400 kV. How many times smaller is the current now, and how many times smaller is the heating loss?
  5. 5At 25 kV, set Resistance of the lines (model) to 5 Ω and count the dark houses. Then tap each row of the bars under the stage in turn and watch the town. What is the lowest transmission voltage that lights all ten houses again?

A transformer on the workbench

The first view is a working transformer on a workbench. On the left, an a.c. supply and a switch feed the primary coil, which is wound on one side of a square iron core built from thin sheets. The secondary coil sits on the opposite side and lights a lamp. Sliders set the input voltage, the number of turns on each coil, the lamp's resistance and the efficiency. Along the bottom, a two-channel trace plots the input and the output against time, each on its own scale, while the core glows purple as its magnetic field grows, shrinks and reverses.

How the turns set the output

The current in the primary keeps changing direction, so the field it makes in the core does too. The core guides that changing field round through the secondary coil, and any coil threaded by a changing field has a p.d. induced across it. Each turn of the secondary picks up the same small p.d., and the turns add together, so the two p.d.s are in the same ratio as the turns:

VpVs=NpNs\frac{V_p}{V_s} = \frac{N_p}{N_s}

AQA writes the turns as npn_p and nsn_s; choose your course under Show symbols for to see its own letters. Fewer turns on the secondary steps the p.d. down, and more turns steps it up. Press Swap to exchange the coils and turn one kind into the other.

Power in, power out

No transformer can make energy. An ideal one passes on all the power it takes from the supply, so VpIp=VsIsV_p I_p = V_s I_s, and whatever happens to the p.d. happens the opposite way to the current. A transformer stepping 12 V up to 48 V draws four times the lamp's current from its supply. Move the Efficiency slider below 100% to model a real transformer, whose coils and core warm up: the output p.d. still follows the turns, but the supply must provide extra power, shown leaking away as heating in the energy-flow diagram.

Why a battery will not do

Press Use d.c. and the supply becomes a battery. Its steady current makes a steady field: the core still glows, yet nothing in it is changing, so nothing is induced and the lamp stays dark. The trace shows a short pulse only at the instants you switch on or off, while the field builds up or collapses. The electromagnetic induction simulation looks at that effect on its own.

One hundred megawatts across the country

Press Grid for the second view. A power station sends out a steady 100 MW from generators at 25 kV, and you choose the transmission voltage: 25 kV with no step-up, or the UK values of 132 kV, 275 kV and 400 kV. The current in the lines is I=P/VI = P/V, and the lines waste P=I2RP = I^2R by heating up. At 25 kV the current is 4000 A, the lines glow on the stage, about a third of the power is lost and three houses in the town stay dark. At 400 kV the current is only 250 A, sixteen times smaller, so the heating falls by 16 × 16 = 256 times. The bars under the stage compare all four voltages, and the Sankey diagram shows where each second's energy ends up.

Inside the model

The lines have a single total resistance, 2 Ω to start with; real values depend on the length and thickness of the route. The grid's transformers are treated as perfect, and a single step-down transformer stands in for the several stages that bring the voltage down to the mains supply. Other countries choose other values, such as roughly 500 kV and 220 kV in Pakistan. The a.c. is slowed right down so you can follow it, the switching pulses are not to scale, and the moving dots show the size of the current rather than charges racing from the power station to your home.

Equations

  • Electrical power (P = IV)

    P=VI

    power = potential difference × current

    Open calculator →
  • Electrical power (P = I²R)

    P=I2R

    power = (current)² × resistance

    Open calculator →
  • Transformer turns ratio

    Vp=VsNpNs

    p.d. across primary coil ÷ p.d. across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

    Open calculator →
  • Transformer power (100% efficient)

    Vp=VsIsIp

    p.d. across primary coil × current in primary coil = p.d. across secondary coil × current in secondary coil

    Open calculator →

Check your understanding

8 questions

  1. 1.Why must a transformer's primary coil be connected to an alternating supply?
  2. 2.A transformer has 400 turns on its primary coil and 2000 on its secondary. The input is 20 V a.c. What is the output?
  3. 3.An ideal transformer steps 230 V down to 23 V, and the current in its output is 5 A. What current does it draw from the supply?
  4. 4.Why does the National Grid send electricity along its cables at a very high voltage?
  5. 5.The same power is sent along the same cables at twice the voltage. What happens to the power wasted heating the cables?
  6. 6.Why is the core of a transformer made of iron?
  7. 7.In the simulation, 100 MW is sent at 25 kV through lines with a total resistance of 2 Ω. What is the current in the lines?
  8. 8.What does the step-down transformer near the homes do?

For teachers

Embed it in your site or open it full-screen for the projector.

Read more