Skip to content

Cambridge IGCSE Physics (0625) · Magnetism and electromagnetic effects

Transformers

4.5.6

Core: a transformer is two coils on a soft-iron core, and Vp/Vs = Np/Ns; step-up transformers raise the voltage for transmission and step-down ones lower it for users. Supplement: how it works, IpVp = IsVs at 100% efficiency, and P = I²R to explain why cables lose less power at a higher voltage.

Loading simulation…

Symbols match your course. Open the full transformers and the national grid simulation for more presets and teacher tools.

What this topic covers

A transformer changes the size of an alternating voltage.

The parts of a transformer (Core)

  • The primary coil takes in energy from an a.c. supply.
  • The secondary coil passes energy on to the output.
  • Both are wound on a soft-iron core.

The coils are insulated wire and are not connected to each other. Soft iron gains and loses its magnetism easily, so the field in the core keeps pace with a reversing current. Transformers are used only with alternating current.

Step-up or step-down? (Core)

VpVs=NpNs\frac{V_p}{V_s} = \frac{N_p}{N_s}

Here VpV_p and VsV_s are the voltages across the primary (p) and secondary (s) coils, and NpN_p and NsN_s are their turns. A step-up transformer has more secondary turns than primary turns, so its output voltage is higher than its input. A step-down transformer has fewer secondary turns and a lower output.

Worked example 1 (Core). A transformer on a pole steps 11 000 V down to 230 V for a street of houses. Its secondary has 46 turns. Find the number of primary turns.

Known values: Vp=11 000V_p = 11\,000 V, Vs=230V_s = 230 V and Ns=46N_s = 46. Rearranging the turns equation and substituting:

Np=Vp×NsVs=11 000×46230=2200N_p = \frac{V_p \times N_s}{V_s} = \frac{11\,000 \times 46}{230} = 2200

Answer: 2200 turns.

How a transformer works (Supplement)

  1. An alternating current flows in the primary coil, so the magnetic field it sets up in the soft-iron core keeps changing in strength and direction.
  2. The core links this changing field with every turn of the secondary coil.
  3. A changing field linking a coil induces an e.m.f. across it, so an alternating voltage appears across the secondary.

With a battery, the current and therefore the field stay constant, so nothing is induced except a brief e.m.f. at the instant of switching on or off.

Power and current (Supplement)

For a 100% efficient transformer, power out equals power in:

IpVp=IsVsI_p V_p = I_s V_s

No energy is created, so stepping the voltage up steps the current down by the same factor. If the pole transformer above supplies 110 A at 230 V, it draws Ip=IsVsVp=110×23011 000=2.3I_p = \dfrac{I_s V_s}{V_p} = \dfrac{110 \times 230}{11\,000} = 2.3 A from the 11 000 V line.

Transmission at high voltage

(Core) Power stations feed their output through a step-up transformer, which raises the voltage before the electricity enters the long-distance cables. Near the users, step-down transformers lower it in stages. Two advantages follow:

  • the current in the cables is smaller, so much less energy is wasted heating them
  • cables with a smaller cross-section are enough, which saves cost

(Supplement) Cables of resistance RR waste power P=I2RP = I^2R, and for a fixed power P=IVP = IV gives the current.

Worked example 2 (Supplement). A hydroelectric station sends 60 MW through cables with a total resistance of 2.5 Ω. Compare the power wasted at 30 kV and at 300 kV.

At 30 kV, I=PV=6.0×10730 000=2000I = \dfrac{P}{V} = \dfrac{6.0 \times 10^7}{30\,000} = 2000 A, so the power lost is I2R=20002×2.5=1.0×107I^2R = 2000^2 \times 2.5 = 1.0 \times 10^7 W: 10 MW, a sixth of the power sent.

At 300 kV, I=6.0×107300 000=200I = \dfrac{6.0 \times 10^7}{300\,000} = 200 A, so the power lost is 2002×2.5=1.0×105200^2 \times 2.5 = 1.0 \times 10^5 W: 0.10 MW, under 0.2%.

Ten times the voltage cuts the loss by a factor of 100.

Simulation tasks

In the simulation above, 230 V a.c. drives the 1000-turn primary, and the secondary has 50 turns and a 5 Ω lamp.

  1. (Core) Work out the output from the turns ratio, then check Output voltage: 11.5 V. (Supplement) Input current × 230 V and Output current × 11.5 V both give about 26.5 W, as shown on Power in and Power out.
  2. (Core) Press Swap: 50 primary and 1000 secondary turns give 4600 V, and a danger warning appears.
  3. (Supplement) Press Use d.c. with the simulation running (Play starts it if paused). The trace shows one pulse, then the lamp stays dark. Off and then On each give one more pulse.
  4. (Core) Press Grid: 100 MW leaves the station at 25 kV, and Heating the lines reads 32.0 MW. Press Raise three times, to 400 kV, and the loss drops to 0.125 MW. (Supplement) Confirm it with P=I2RP = I^2R, using the 250 A in Current in the lines and the 2 Ω line resistance.

The grid voltages in the simulation are UK values. The 0625 syllabus does not ask you to learn any particular grid voltage.

Equations

  • Transformer turns ratio

    Learn this

    Vp=VsNpNs

    p.d. across primary coil ÷ p.d. across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

    Open calculator →
  • Transformer power (100% efficient)

    Learn this · Supplement

    Vp=VsIsIp

    p.d. across primary coil × current in primary coil = p.d. across secondary coil × current in secondary coil

    Open calculator →
  • Electrical power (P = I²R)

    Learn this · Supplement

    P=I2R

    power = (current)² × resistance

    Open calculator →

Common mistakes

  • Turning one side of the turns equation upside down, for example writing Vp/Vs = Ns/Np. Both sides must have the primary on top, or both the secondary.
  • Calling a transformer step-up because its primary has more turns. A step-up transformer has more turns on its secondary, so its output voltage is the larger one.
  • Saying soft iron is used because it is a good conductor. It is used because it magnetises and demagnetises easily; the coils are not connected through the core or by any wire.
  • (Supplement) Assuming that stepping up the voltage steps up the current as well. With IpVp = IsVs, the current falls by the same factor that the voltage rises.
  • (Supplement) Saying a transformer works on d.c. because a battery still magnetises the core. A constant field induces no e.m.f.; only a changing field does.
  • (Supplement) Finding the cable loss from the transmission voltage, as V²/R. The voltage across the cables is far smaller than the transmission voltage, so find the current with I = P/V and then use P = I²R.

Exam-style questions

Original questions written in the style of Cambridge IGCSE. Try each one before you reveal the answer.

  1. 1.A student in Nairobi builds a simple transformer from a soft-iron core and two coils of insulated wire. The primary coil has 400 turns and is connected to a 6.0 V a.c. supply. The secondary coil has 2000 turns.

    1. (a)State what is meant by the primary coil and by the secondary coil.

      2 marks
      Show the answer

      Answer: The primary coil is the input coil, connected to the supply. The secondary coil is the output coil, connected to the load.

      Marking points

      • primary: the input coil / the coil connected to the (a.c.) supply
      • secondary: the output coil / the coil connected to the load
    2. (b)Calculate the voltage across the secondary coil.

      2 marks
      Show the answer

      Answer: Vs = Vp × Ns ÷ Np = 6.0 × 2000 ÷ 400 = 30 V

      Marking points

      • Vp/Vs = Np/Ns or 6.0 × 2000 ÷ 400
      • 30 V
    3. (c)State whether this transformer is step-up or step-down. Give a reason.

      2 marks
      Show the answer

      Answer: Step-up: the secondary has more turns than the primary, so the output voltage is greater than the input voltage.

      Marking points

      • step-up
      • more turns on the secondary (output voltage greater than input voltage)
    4. (d)Suggest why the core is made of soft iron.

      1 mark
      Show the answer

      Answer: Soft iron is easily magnetised and demagnetised.

      Marking points

      • easily magnetised (and demagnetised)
  2. 2.A hydroelectric power station sends electrical power to a distant city along overhead transmission cables. Transformers are used at both ends of the cables.

    1. (a)State where a step-up transformer is used and where a step-down transformer is used in this system.

      2 marks
      Show the answer

      Answer: Step-up: at the power station, between the generator and the transmission cables. Step-down: near the city, between the cables and the consumers.

      Marking points

      • step-up at the power station (before the transmission cables)
      • step-down near the city / the consumers (after the transmission cables)
    2. (b)State two advantages of transmitting electrical power at a very high voltage.

      2 marks
      Show the answer

      Answer: Less power is lost as heat in the cables. The current is smaller, so thinner and cheaper cables can be used.

      Marking points

      • less power (energy) lost, as thermal energy, in the cables
      • smaller current, so thinner (lighter / cheaper) cables can be used
    3. (c)(Supplement) The station transmits 80 MW at 400 kV. The cables have a total resistance of 15 Ω. Calculate the power lost in the cables.

      3 marks
      Show the answer

      Answer: I = P ÷ V = 80 000 000 ÷ 400 000 = 200 A. Power lost = I²R = 200² × 15 = 600 000 W (0.60 MW).

      Marking points

      • I = 80 000 000 ÷ 400 000 = 200 A
      • P = I²R = 200² × 15
      • 600 000 W (0.60 MW)
    4. (d)(Supplement) Explain, with a calculation, why the power lost would be much greater if the same power were transmitted at 100 kV.

      3 marks
      Show the answer

      Answer: At 100 kV the current would be 80 000 000 ÷ 100 000 = 800 A, four times as large. Since the loss is I²R, four times the current gives 4² = 16 times the loss: 800² × 15 = 9 600 000 W.

      Marking points

      • current = 800 A (four times as large)
      • the loss is I²R, so four times the current gives sixteen times the loss
      • 9 600 000 W (9.6 MW), 16 times as much
  3. 3.A battery charger contains a transformer that steps an a.c. supply of 220 V down to 11 V. The transformer is 100% efficient.

    1. (a)(Supplement) Explain how the transformer produces an alternating voltage across its secondary coil.

      3 marks
      Show the answer

      Answer: An alternating current flows in the primary coil, so the magnetic field it sets up in the soft-iron core changes continually. The core links this changing field with the secondary coil, where it induces an alternating e.m.f. (voltage).

      Marking points

      • alternating current in the primary gives a changing magnetic field in the core
      • the core links the changing field with the secondary coil
      • an (alternating) e.m.f. / voltage is induced across the secondary by the changing field
    2. (b)The primary coil has 1200 turns. Find the number of secondary turns.

      2 marks
      Show the answer

      Answer: Ns = Vs × Np ÷ Vp = 11 × 1200 ÷ 220 = 60 turns

      Marking points

      • Ns = 11 × 1200 ÷ 220 (or 220/11 = 1200/Ns)
      • 60 (turns)
    3. (c)(Supplement) The current in the secondary coil is 3.0 A. Calculate the current in the primary coil.

      2 marks
      Show the answer

      Answer: IpVp = IsVs, so Ip = IsVs ÷ Vp = 3.0 × 11 ÷ 220 = 0.15 A

      Marking points

      • Ip × 220 = 3.0 × 11
      • 0.15 A
    4. (d)(Supplement) Explain why the transformer would not work if its primary coil were connected to a battery.

      2 marks
      Show the answer

      Answer: A battery gives a constant (d.c.) current, so the magnetic field in the core is constant. An unchanging field induces no e.m.f. across the secondary, apart from a brief one at the moment of switching on or off.

      Marking points

      • d.c. / a constant current gives a constant (unchanging) magnetic field
      • the field does not change, so no e.m.f. (voltage) is induced across the secondary
  4. 4.A laboratory transformer has a primary coil of 240 turns connected to a 12 V a.c. supply. Secondary coils of 60, 120, 480 and 960 turns can be fitted on the same core.

    1. (a)Calculate the output voltage when the 960-turn coil is used.

      2 marks
      Show the answer

      Answer: Vs = Vp × Ns ÷ Np = 12 × 960 ÷ 240 = 48 V

      Marking points

      • 12 × 960 ÷ 240
      • 48 V
    2. (b)State which secondary coil gives an output of 3.0 V.

      1 mark
      Show the answer

      Answer: The 60-turn coil, since 12 × 60 ÷ 240 = 3.0 V.

      Marking points

      • 60 turns
    3. (c)State which of the four coils make the transformer step-down.

      1 mark
      Show the answer

      Answer: The 60-turn and 120-turn coils, which have fewer turns than the primary.

      Marking points

      • 60 and 120 turns (both needed)

Quick check

6 questions

  1. 1.Which part of a transformer is connected to the a.c. supply?
  2. 2.A transformer has 50 turns on its primary and 1000 turns on its secondary. The input voltage is 12 V. What is the output voltage?
  3. 3.Which is an advantage of transmitting electrical energy at a high voltage?
  4. 4.(Supplement) A 100% efficient transformer takes 0.50 A from a 240 V supply. Its output voltage is 12 V. What is the output current?
  5. 5.(Supplement) Why does a transformer give no steady output when its primary is connected to a battery?
  6. 6.(Supplement) The voltage used to send a fixed power along the same cables is raised from 100 kV to 500 kV. How does the power lost in the cables change?