Who needs this: Higher tier, GCSE Physics only
Spec point 4.7.3.4 appears only on Higher tier papers in GCSE Physics, not on Foundation papers or Combined Science. Both equations are on the Physics equation sheet, so the skill is choosing and using them. Be ready to:
- name the parts of a basic transformer and say why the core is iron
- explain how an alternating current in the primary produces an output from the secondary
- link the p.d. across each coil to its number of turns, and find the current a supply must provide
- use both equations to explain why the grid transmits at a high p.d.
Laminated cores are not examined. The grid itself, for every student, is on The National Grid page.
What is inside
Two coils of insulated wire share one iron core. The primary coil is joined to the a.c. supply, and the secondary coil to whatever the transformer powers. No wire runs from one coil to the other. Iron magnetises readily, so a modest current in the primary sets up a strong magnetic field in the core.
How the secondary gets its p.d.
- The supply drives an alternating current through the primary. As this current rises, falls and reverses, so does the magnetic field it produces in the core.
- The core guides the field round, so the same changing field passes through every turn of the secondary.
- A changing magnetic field induces a potential difference across a coil: the generator effect. So the output is an alternating p.d., and a lamp connected across the secondary carries an induced alternating current.
A battery gives a steady current, so the field soon stops changing and nothing is induced, apart from a short pulse at the moment of connecting or disconnecting. Transformers therefore need a.c.
Turns and potential difference
is the p.d. across the primary coil and the p.d. across the secondary, both in volts; and count the turns on each. In an ideal transformer every turn of both coils has the same changing field through it, so each turn has the same p.d. A coil with twice as many turns has twice the p.d.
- Step-up: more turns on the secondary, so is greater than .
- Step-down: fewer turns on the secondary, so is less than .
Worked example 1: a doorbell. A transformer steps 230 V mains down to 8.0 V. Its primary coil has 1150 turns. How many turns are on its secondary?
Given: V, V, . Equation: rearrange to . Substitution: . Answer: turns.
Power in, power out
A transformer never creates energy. At 100% efficiency, the power delivered by the secondary equals the power taken by the primary:
So the current changes the opposite way to the p.d.: stepping the p.d. up 10 times leaves one tenth of the current. Real transformers waste a little energy as heat; questions say when to assume 100%.
Worked example 2: what the mains supplies. The doorbell's chime takes 0.50 A from the 8.0 V secondary. Assuming 100% efficiency, find the primary current.
Given: V, A, V. Equation: rearrange to . Substitution: . Answer: A (2 s.f.).
This explains the grid: stepping 25 kV up 11 times, to 275 kV, makes the current 11 times smaller, so cable heating, , falls times.
Check the equations yourself
In the simulation above, the 230 V a.c. supply feeds a 1000-turn primary, and a 50-turn secondary lights a 5 Ω lamp.
- Predict the output from the turns ratio, then read Output p.d.: 11.5 V. Output current is 2.30 A but Input current only 0.115 A, 20 times less; Power in and Power out both show 26.5 W.
- Choose 12 V up to 48 V from Examples. Use the two current cards to check that . Predict the output after Swap, then press it: 3.00 V.
- Press Use d.c. and let the simulation run (press Play if it is paused). After one short pulse the output stays at 0 V. Press Off, then On: there is a pulse only while the field changes.
- Choose 12 V up to 48 V again and set Efficiency (model) to 80%, a model of real losses. The output stays at 48.0 V, but Power in becomes 60.0 W and Input current rises to 5.00 A.