Skip to content

GCSE Physics — AQA · Magnetism and electromagnetism

Transformers

4.7.3.4Higher tierPhysics only

Higher tier, GCSE Physics only. A transformer has a primary and a secondary coil on an iron core. An alternating current in the primary makes a changing field, which induces an alternating p.d. in the secondary. Use Vp/Vs = np/ns and, at 100% efficiency, Vs × Is = Vp × Ip (equation sheet).

Loading simulation…

Symbols match your course. Open the full transformers and the national grid simulation for more presets and teacher tools.

Who needs this: Higher tier, GCSE Physics only

Spec point 4.7.3.4 appears only on Higher tier papers in GCSE Physics, not on Foundation papers or Combined Science. Both equations are on the Physics equation sheet, so the skill is choosing and using them. Be ready to:

  • name the parts of a basic transformer and say why the core is iron
  • explain how an alternating current in the primary produces an output from the secondary
  • link the p.d. across each coil to its number of turns, and find the current a supply must provide
  • use both equations to explain why the grid transmits at a high p.d.

Laminated cores are not examined. The grid itself, for every student, is on The National Grid page.

What is inside

Two coils of insulated wire share one iron core. The primary coil is joined to the a.c. supply, and the secondary coil to whatever the transformer powers. No wire runs from one coil to the other. Iron magnetises readily, so a modest current in the primary sets up a strong magnetic field in the core.

How the secondary gets its p.d.

  1. The supply drives an alternating current through the primary. As this current rises, falls and reverses, so does the magnetic field it produces in the core.
  2. The core guides the field round, so the same changing field passes through every turn of the secondary.
  3. A changing magnetic field induces a potential difference across a coil: the generator effect. So the output is an alternating p.d., and a lamp connected across the secondary carries an induced alternating current.

A battery gives a steady current, so the field soon stops changing and nothing is induced, apart from a short pulse at the moment of connecting or disconnecting. Transformers therefore need a.c.

Turns and potential difference

VpVs=npns\frac{V_p}{V_s} = \frac{n_p}{n_s}

VpV_p is the p.d. across the primary coil and VsV_s the p.d. across the secondary, both in volts; npn_p and nsn_s count the turns on each. In an ideal transformer every turn of both coils has the same changing field through it, so each turn has the same p.d. A coil with twice as many turns has twice the p.d.

  • Step-up: more turns on the secondary, so VsV_s is greater than VpV_p.
  • Step-down: fewer turns on the secondary, so VsV_s is less than VpV_p.

Worked example 1: a doorbell. A transformer steps 230 V mains down to 8.0 V. Its primary coil has 1150 turns. How many turns are on its secondary?

Given: Vp=230V_p = 230 V, Vs=8.0V_s = 8.0 V, np=1150n_p = 1150. Equation: rearrange to ns=np×VsVpn_s = \dfrac{n_p \times V_s}{V_p}. Substitution: ns=1150×8.0230n_s = \dfrac{1150 \times 8.0}{230}. Answer: ns=40n_s = 40 turns.

Power in, power out

A transformer never creates energy. At 100% efficiency, the power delivered by the secondary equals the power taken by the primary:

Vs×Is=Vp×IpV_s \times I_s = V_p \times I_p

So the current changes the opposite way to the p.d.: stepping the p.d. up 10 times leaves one tenth of the current. Real transformers waste a little energy as heat; questions say when to assume 100%.

Worked example 2: what the mains supplies. The doorbell's chime takes 0.50 A from the 8.0 V secondary. Assuming 100% efficiency, find the primary current.

Given: Vs=8.0V_s = 8.0 V, Is=0.50I_s = 0.50 A, Vp=230V_p = 230 V. Equation: rearrange to Ip=Vs×IsVpI_p = \dfrac{V_s \times I_s}{V_p}. Substitution: Ip=8.0×0.50230I_p = \dfrac{8.0 \times 0.50}{230}. Answer: Ip=0.017I_p = 0.017 A (2 s.f.).

This explains the grid: stepping 25 kV up 11 times, to 275 kV, makes the current 11 times smaller, so cable heating, I2RI^2R, falls 112=12111^2 = 121 times.

Check the equations yourself

In the simulation above, the 230 V a.c. supply feeds a 1000-turn primary, and a 50-turn secondary lights a 5 Ω lamp.

  1. Predict the output from the turns ratio, then read Output p.d.: 11.5 V. Output current is 2.30 A but Input current only 0.115 A, 20 times less; Power in and Power out both show 26.5 W.
  2. Choose 12 V up to 48 V from Examples. Use the two current cards to check that 12×4.00=48×1.0012 \times 4.00 = 48 \times 1.00. Predict the output after Swap, then press it: 3.00 V.
  3. Press Use d.c. and let the simulation run (press Play if it is paused). After one short pulse the output stays at 0 V. Press Off, then On: there is a pulse only while the field changes.
  4. Choose 12 V up to 48 V again and set Efficiency (model) to 80%, a model of real losses. The output stays at 48.0 V, but Power in becomes 60.0 W and Input current rises to 5.00 A.

Equations

  • Transformer turns ratio

    On the equation sheet · Higher tier · Physics only

    Vp=Vsnpns

    p.d. across primary coil ÷ p.d. across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

    Open calculator →
  • Transformer power (100% efficient)

    On the equation sheet · Higher tier · Physics only

    Vp=VsIsIp

    p.d. across primary coil × current in primary coil = p.d. across secondary coil × current in secondary coil

    Open calculator →

Common mistakes

  • Writing a fraction with a primary value on top on one side of the turns equation and a secondary value on top on the other. Keep the same pattern on both sides: Vp/Vs = np/ns.
  • Thinking a step-up transformer gives out more power than it takes in. The p.d. goes up but the current comes down; at 100% efficiency the power out only equals the power in.
  • Saying the core is iron because iron conducts electricity. Iron is chosen because it is easily magnetised, and no current passes through the core from one coil to the other.
  • Expecting a transformer to work from a battery. Direct current makes a steady field, and a steady field induces no p.d., apart from a brief pulse as the battery is connected or disconnected.
  • Mixing units in one equation, such as Vp in kilovolts and Vs in volts. Convert both to the same unit before substituting.
  • Not checking whether an answer makes sense. A step-down transformer must give a smaller p.d. and a larger current than it takes in.

Exam-style questions

Original questions written in the style of GCSE AQA. Try each one before you reveal the answer.

  1. 1.Higher tier, physics only. A transformer has an iron core with two coils of insulated wire around it. The primary coil is connected to an alternating current supply. The secondary coil is connected to a lamp.

    1. (a)Give the reason why iron is used for the core.

      1 mark
      Show the answer

      Answer: Iron is easily magnetised.

      Marking points

      • (Iron) is easily magnetised.
    2. (b)Explain how the transformer causes a potential difference across the secondary coil.

      4 marks
      Show the answer

      Answer: The primary coil carries an alternating current, which sets up a magnetic field in the iron core. As the current keeps changing, so does the field, in both strength and direction. The iron core channels the changing field round to the secondary coil, and a changing field induces an alternating potential difference across it.

      Marking points

      • The alternating current in the primary sets up a magnetic field in the core.
      • The field is constantly changing (in strength and direction).
      • The (iron) core channels the changing field to the secondary coil.
      • A changing field induces an (alternating) p.d. across the secondary coil.
    3. (c)The alternating supply is replaced with a battery. A data logger across the secondary coil records a short pulse of p.d. when the battery is connected, then zero. Explain these results.

      3 marks
      Show the answer

      Answer: When the battery is connected, the current in the primary grows from zero, so the field in the core changes for a moment and a brief p.d. is induced. Once the current is steady, the field is constant. A constant field induces no p.d., so the reading falls to zero.

      Marking points

      • At connection the current, and so the field, grows from zero; this change induces a brief p.d.
      • Once the direct current is steady, the field in the core stays constant.
      • A constant field induces no p.d., so the reading drops to zero.
  2. 2.Higher tier, physics only. A model railway uses a transformer to step the 230 V mains supply down to 16 V. The secondary coil has 112 turns.

    1. (a)State whether this is a step-up or a step-down transformer. Give a reason for your answer.

      2 marks
      Show the answer

      Answer: Step-down, because the output p.d. (16 V) is less than the input p.d. (230 V).

      Marking points

      • Step-down
      • The p.d. across the secondary (16 V) is less than the p.d. across the primary (230 V) (allow: the secondary has fewer turns).
    2. (b)Calculate the number of turns on the primary coil.

      3 marks
      Show the answer

      Answer: Vp/Vs = np/ns, so np = ns × Vp ÷ Vs = 112 × 230 ÷ 16 = 1610 turns.

      Marking points

      • 230 ÷ 16 = np ÷ 112
      • np = 112 × 230 ÷ 16
      • np = 1610 (turns)
    3. (c)The train's motor draws a current of 1.5 A from the secondary coil. The transformer is 100% efficient. Calculate the current in the primary coil. Give your answer to 2 significant figures.

      3 marks
      Show the answer

      Answer: Vs × Is = Vp × Ip, so Ip = Vs × Is ÷ Vp = 16 × 1.5 ÷ 230 = 0.104 A, which is 0.10 A to 2 significant figures.

      Marking points

      • 16 × 1.5 = 230 × Ip
      • Ip = 24 ÷ 230 (= 0.104 A)
      • Ip = 0.10 A (to 2 significant figures)
  3. 3.Higher tier, physics only. At a power station, a generator supplies 330 MW at a potential difference of 25 kV to the primary coil of a step-up transformer. The p.d. across the secondary coil is 275 kV. The transformer is 100% efficient.

    1. (a)Calculate the current in the primary coil.

      2 marks
      Show the answer

      Answer: Ip = P ÷ Vp = 330 000 000 ÷ 25 000 = 13 200 A

      Marking points

      • 330 000 000 ÷ 25 000
      • 13 200 A
    2. (b)Calculate the current in the secondary coil.

      2 marks
      Show the answer

      Answer: Vs × Is = Vp × Ip, so Is = 25 000 × 13 200 ÷ 275 000 = 1200 A.

      Marking points

      • 275 000 × Is = 25 000 × 13 200 (or Is = 330 000 000 ÷ 275 000)
      • Is = 1200 A
    3. (c)The primary coil has 400 turns. Calculate how many turns are on the secondary coil.

      2 marks
      Show the answer

      Answer: ns = np × Vs ÷ Vp = 400 × 275 000 ÷ 25 000 = 4400 turns

      Marking points

      • 25 000 ÷ 275 000 = 400 ÷ ns (or ns = 400 × 275 000 ÷ 25 000)
      • ns = 4400 (turns)
    4. (d)Explain why sending the power at 275 kV rather than at 25 kV reduces the energy wasted in the transmission cables.

      3 marks
      Show the answer

      Answer: For the same power, the current in the cables is smaller: 1200 A instead of 13 200 A. Cable heating is given by I²R, which goes up with the square of the current. With the current 11 times smaller, the energy wasted heating the cables each second is 121 times smaller.

      Marking points

      • The current in the cables is smaller for the same power.
      • Heating power = I²R, which is proportional to the current squared.
      • So much less energy is dissipated heating the cables (121 times less).
  4. 4.Higher tier, physics only. A student connects the primary coil of a demonstration transformer to a 12 V a.c. supply. The primary coil has 300 turns. The student tries secondary coils with different numbers of turns and records the p.d. across each one. Results: 50 turns, 2.0 V; 100 turns, 4.0 V; 150 turns, 6.0 V; 200 turns, 8.0 V.

    1. (a)Describe how the p.d. across the secondary coil depends on how many turns it has.

      2 marks
      Show the answer

      Answer: The p.d. is directly proportional to the number of turns: doubling the turns doubles the p.d.

      Marking points

      • As the number of turns increases, the p.d. increases.
      • Directly proportional (e.g. doubling the turns doubles the p.d.).
    2. (b)Show that the result for 150 turns agrees with the equation Vp/Vs = np/ns.

      2 marks
      Show the answer

      Answer: Vp ÷ Vs = 12 ÷ 6.0 = 2.0 and np ÷ ns = 300 ÷ 150 = 2.0. The two ratios are equal.

      Marking points

      • 12 ÷ 6.0 = 2.0
      • 300 ÷ 150 = 2.0, so the two ratios are equal
    3. (c)Predict the number of turns needed on the secondary coil for the output p.d. to equal the input p.d.

      1 mark
      Show the answer

      Answer: 300 turns, the same number as on the primary coil.

      Marking points

      • 300 (turns), the same as the primary
    4. (d)The student says: 'With 600 turns on the secondary coil, the transformer would give out more power than it takes in.' Explain why the student is wrong.

      2 marks
      Show the answer

      Answer: With 600 turns the p.d. would rise to 24 V, but a transformer cannot create energy. At best the power out equals the power in (Vs × Is = Vp × Ip), so the current in the secondary would be smaller than the current in the primary.

      Marking points

      • Energy cannot be created, so the power out cannot be more than the power in (at best Vs × Is = Vp × Ip).
      • The p.d. goes up but the current goes down (by the same factor).

Quick check

6 questions

  1. 1.What makes iron a good choice for the core of a transformer?
  2. 2.A transformer has 200 turns on its primary coil and 3000 turns on its secondary coil. The p.d. across the primary is 16 V. What is the p.d. across the secondary?
  3. 3.A 100% efficient transformer draws 0.40 A from a 230 V supply. The p.d. across its secondary is 46 V. What is the current in the secondary?
  4. 4.The primary coil of a transformer is connected to a battery and left connected. What is the p.d. across the secondary once the current has settled?
  5. 5.Which statement about a 100% efficient step-up transformer is correct?
  6. 6.A step-up transformer raises a p.d. 20 times before a fixed power is sent along a cable. How does the power wasted heating the cable change?