Skip to content

Electricity simulation

Mains Electricity and Safety Simulation

Four linked scenes: wire a fused three-pin plug and have it checked, make a live wire touch a kettle's case with and without an earth wire, pick the right fuse for an appliance from its current, and see breakers, fuses and an RCD guard the circuits of a home.

Loading simulation…
Show symbols for

Predict first

Question 1 of 4

A kettle has a metal case joined to the earth wire and a fuse in the live wire. Inside, the live wire works loose and touches the case. What happens?

Try this

  1. 1On the Plug scene, drag each coloured core onto its terminal (or pick a Core and use Screwed into), turn on Cable grip tightened on the sheath and Fuse fitted (13 A), then press Check. Next, choose Plug to inspect 1 under Start from and press Check: what has gone wrong, and why is it dangerous?
  2. 2Open Faults with Earthed metal case and press Fault. Follow the red path from the live core through the case and the earth wire, and watch the fuse. Press Repair, choose No earth wire and make the same fault: which card turns red, and does the fuse melt?
  3. 3Keep No earth wire, press Switch off, then Fault. Read the status line: does switching the kettle off make its case safe? Then try Fuse in neutral with Short circuit and compare the L and N labels inside the kettle.
  4. 4In Fuse, choose the Hairdryer (1 kW). Work out I = P ÷ V using the Mains p.d. card before you look at the Normal current card, then try each fuse rating: press Switch on, then Fault, and watch the current scale.
  5. 5In Home, turn on the Kettle and the Fan heater together and wait. Press Reset, switch one off, then repeat with Fuses instead of Circuit breakers. Finally press Damp, first with RCD fitted (30 mA) on and then off.

Four scenes, one cable

Each scene follows the same three-core cable. The live core brings the alternating p.d. from the supply, the neutral core completes the circuit at close to 0 V, and the earth core sits at 0 V, joined to any metal case. Every core carries the letter L, N or E as well as its colour, so you never have to rely on colour alone. The mains value comes from the course you pick: 230 V at 50 Hz for GCSE and IGCSE, 220 V at 50 Hz for Pakistan and India, and 120 V at 60 Hz for the USA. These are the commonly quoted figures. India's official nominal value is 230 V, and the real p.d. at a socket varies a little.

Wiring the plug

The plug is the fused UK type, seen from behind with its clear cover lifted off. Drag each core to a terminal, choose how much insulation to strip, and decide whether the strands are twisted tight. Then tighten the cable grip on the outer sheath and clip in the fuse. Press Check and every mistake is listed with its consequence: copper clamped under plastic can overheat, a stray strand can bridge two terminals, and an earth core screwed to the live terminal would make a metal case live. Swapping live and neutral is subtler. The appliance still runs, but its own switch then sits on the neutral side, so its insides stay live after it is switched off.

Making a fault

A metal kettle is plugged in and its live core wears through where the cable enters. With an earth wire, the fault current takes the easy path to earth, over a hundred amps in this model, and the fuse melts within a fraction of a second. Without one, nothing extra flows. The fuse stays whole, the kettle may carry on working, and its case sits at the mains p.d. until something, or someone, gives the current a path to earth. A double-insulated hairdryer shows the other solution: a case that cannot conduct. Finally, a fuse wrongly placed in the neutral melts during a short circuit but leaves the kettle joined to the live supply.

Choosing a fuse

Pick an appliance and the sim works out its normal current:

I=PVI = \frac{P}{V}

The right fuse is the smallest standard rating above that current. Too small, and it melts the moment you switch on. Too big, and an overload that the cable cannot handle may not melt it, so the cable overheats instead. A current scale marks the normal current, the cable's safe limit, the fuse rating and the fault current, so you can see why the gap matters. Hide the current in a lesson link and students must calculate it first.

Protecting a home

The last scene is a consumer unit feeding two circuits in parallel. Switch on a kettle and a heater together and the sockets circuit is overloaded, so its breaker trips. Swap to fuses to compare: a breaker can be reset, while a melted fuse must be replaced. A short circuit trips it almost at once. Damp leaking a few hundredths of an amp to earth is far too small for any fuse, but the residual-current device notices that the live and neutral currents no longer match and switches everything off.

What your course expects

AQA names the three wires, their colours and their p.d.s, but not fuses, breakers, RCDs or plug wiring, which are labelled as extras. Cambridge IGCSE makes fuses, trip switches, earthing and double insulation Core. The Punjab Physics 10 book covers household circuits and safety measures in Chapter 16. Mains electricity can kill, so leave real wiring to a qualified electrician.

Equations

Check your understanding

8 questions

  1. 1.Which wire in a three-core mains cable is a safety wire that normally carries no current?
  2. 2.A lamp is switched off at a switch in the live wire. Why is the live wire up to the switch still dangerous to touch?
  3. 3.A 2.0 kW fan heater runs on 230 V mains. What is its normal current?
  4. 4.Plug fuses of 3 A, 5 A and 13 A are available. Which one should the 8.7 A fan heater have?
  5. 5.The live wire touches the earthed metal case of a toaster. What makes the fuse melt?
  6. 6.Why does a double-insulated hairdryer not need an earth wire?
  7. 7.Why must the fuse in a plug be connected in the live wire?
  8. 8.Compared with a fuse, what is one advantage of a circuit breaker?

For teachers

Embed it in your site or open it full-screen for the projector.

Read more