What is on the bench
Pick one of three experiments. Heating curve puts crushed ice, straight from a freezer and colder than 0 °C, into a closed container with an electric heater, a joulemeter, a digital thermometer and a stopwatch. Melting practical sets up two funnels of melting ice above beakers on balances, with a heater in one funnel only. Cooling curve lets a tube of molten stearic acid cool in the air. A chip on the stage shows how much faster than real life each run plays.
Reading the heating curve
The temperature–time graph has five parts. It slopes up while the ice warms, goes flat at 0 °C while the ice melts, slopes up again as the water warms, goes flat at 100 °C while the water boils, and finally climbs as the steam warms. The flat parts are where the state changes.
Along a sloping part the temperature climbs by for every joule supplied, so with steady power and no losses the gradient is . Ice and steam both have specific heat capacities close to 2000 J/(kg °C), about half the value for water, so their lines are roughly twice as steep.
On a flat part the energy changes the state instead:
With the starting settings, melting the 0.50 kg of ice takes J, while boiling the water away needs J. With no losses, a 500 W heater supplies those in 334 s and 2260 s, so the boiling plateau lasts almost seven times as long. The Stage by stage panel lists the energy for every stage and sets it beside the joulemeter readings.
Why the temperature stops rising
While the reading on a plateau stays fixed, the average kinetic energy of the particles stays fixed too. The internal energy still rises, because the energy goes into the potential energy of the particles as their arrangement breaks up. The particle panel on the stage tracks both: its kinetic energy bar holds still on a plateau while the internal energy bar keeps climbing.
Measuring L, and which way the error goes
You can find L from any plateau. Note the joulemeter where the flat part starts and where it ends, then divide the difference by the mass. With No losses you get the accepted values. With real insulation the two answers drift in opposite directions. While the ice is colder than the room, the room helps to melt it, so the joulemeter shows less than mL and L comes out low. While the water boils, the heater must also replace energy escaping to the room, so L comes out high.
The melting practical handles the room's share with a control funnel that has no heater. Both funnels take in the same energy from the room, so subtracting the control's meltwater leaves the ice melted by the heater alone. A small error remains: some of the heater's energy warms the air rather than the ice, so even the corrected value is a little too big.
Cooling curves
Molten stearic acid cools quickly at first, then holds at about 69 °C while it freezes, then cools again as a solid. On the flat part it is still losing energy to the air, but freezing releases latent heat just as fast. Change the mass and watch the flat part grow or shrink. To focus on the sloping parts alone, try the specific heat capacity simulation.