Skip to content

How to Read an Oscilloscope Trace: Timebase, Y-Gain, Period and Frequency

An oscilloscope trace is a graph of p.d. against time. Learn what the timebase and Y-gain controls do, how to read the period and work out the frequency with f = 1/T, how to find the peak p.d., and how to compare two traces for pitch and loudness without unit slips.

Published · 8 min read

On this page

An oscilloscope trace is a graph. Time runs across the screen from left to right, and potential difference (p.d.) runs up the screen. The screen is split into squares called divisions. Two settings tell you what each division is worth. The timebase gives the time for one division across. The Y-gain gives the p.d. for one division up.

So reading a trace takes two short calculations. For the period, count how many divisions one complete wave spans, then multiply that number by the timebase. The frequency is then f=1/Tf = 1/T, with T in seconds. For the peak p.d., measure how many divisions a peak rises above the centre line, then multiply by the Y-gain.

What does an oscilloscope trace actually show?

An oscilloscope displays a p.d. that changes with time. In sound experiments, a microphone turns the sound into that p.d. In the simplest picture, the trace rises when a compression reaches the microphone and the air pressure there goes up. It falls when a rarefaction arrives and the pressure drops.

So the trace is not a picture of the sound wave. Sound is longitudinal: layers of air move back and forth along the direction the sound travels. They do not move across that direction, as the wavy line might suggest. The wavy line only shows how the signal at one place changes from moment to moment.

Many oscilloscopes have a grid 10 divisions wide and 8 divisions high, with a centre line across the middle. The same reading method works for an electrical signal connected straight to the input, such as the output of a low-voltage a.c. supply.

What do the timebase and Y-gain controls do?

The timebase sets how much time each horizontal division stands for. It is marked in seconds per division (s/div), milliseconds per division (ms/div) or microseconds per division (µs/div). At 2 ms/div, the spot takes 2 ms to cross one division, so a 10-division screen shows 20 ms of signal.

The Y-gain sets how much p.d. each vertical division stands for. It is marked in volts per division (V/div) or millivolts per division (mV/div).

Neither control changes the signal. They only change how it is drawn, a bit like zooming in or out on a graph:

  • More time per division squeezes more waves onto the screen. Less time per division stretches each wave out.
  • More volts per division makes the trace shorter. Fewer volts per division makes it taller.

Phrases like "turn the Y-gain up" are easy to misread, because a bigger number on the dial gives a smaller trace. To avoid confusion, describe a setting by its number: more or fewer volts per division.

How do you find the period and the frequency?

  1. Pick two matching points on the trace, such as two neighbouring peaks. Two places where the trace crosses the centre line going upwards also work.
  2. Count the divisions between them. That is one complete wave.
  3. Multiply by the timebase to get the period.
  4. Convert the period into seconds.
  5. Use f=1Tf = \dfrac{1}{T} to find the frequency in hertz (Hz).

For a more accurate result, measure across several complete waves and divide by the number of waves. Any small reading error is then shared between them.

Worked example 1: a steady note in Lagos

A student in Lagos points a microphone at a loudspeaker playing a steady note. The timebase is 1 ms/div and the Y-gain is 5 mV/div. One complete wave covers 2.5 divisions. The peaks reach 3.0 divisions above the centre line. Work out T, then f, then the peak p.d.

Step 1, the period: T=2.5×1=2.5T = 2.5 \times 1 = 2.5 ms =0.0025= 0.0025 s

Step 2, the frequency: f=1T=10.0025=400f = \dfrac{1}{T} = \dfrac{1}{0.0025} = 400 Hz

Step 3, the peak p.d.: 3.0×5=153.0 \times 5 = 15 mV

Answer: the period is 2.5 ms, the frequency is 400 Hz and the peak p.d. is 15 mV.

Worked example 2: ultrasound in standard form

In a school lab in Delhi, an ultrasound receiver is connected to an oscilloscope set to 10 µs/div. Exactly four complete waves fill the 10 divisions across the screen. Find the frequency and say whether people could hear it.

Divisions for one wave: 10÷4=2.510 \div 4 = 2.5 div

Period: T=2.5×10 μs=25 μs=2.5×10−5T = 2.5 \times 10\ \mu\text{s} = 25\ \mu\text{s} = 2.5 \times 10^{-5} s

Frequency: f=12.5×10−5=4.0×104f = \dfrac{1}{2.5 \times 10^{-5}} = 4.0 \times 10^{4} Hz

Answer: 40 000 Hz, or 40 kHz. This is well above the top of the human hearing range, about 20 kHz, so it is ultrasound.

Keep the prefixes straight: 1 ms is 10−310^{-3} s and 1 µs is 10−610^{-6} s.

How do you read the peak p.d.?

Measure the peak p.d. from the centre line to the top of a peak. The distance from the bottom of a trough to the top of a peak is the peak-to-peak value, which is twice as big. If the centre line is hard to see, measure peak to peak and halve it.

For sound, a taller trace means a bigger amplitude, and so a louder sound. But the height on the screen also depends on the Y-gain, the microphone and how far it is from the source. Compare heights only when all of those stay the same.

How do you compare two traces for pitch and loudness?

Pitch depends on frequency, and loudness depends on amplitude. If both traces use the same timebase and Y-gain:

  • More waves across the screen, each covering fewer divisions, means a higher frequency and so a higher pitch.
  • Taller peaks mean a bigger amplitude and so a louder sound.
  • A different shape, with the same spacing and height, means the same pitch and loudness but a different quality (timbre). That is why a flute and a violin playing the same note still sound different.

Worked example 3: comparing two notes

Two notes are recorded at 2 ms/div and 10 mV/div. In trace A, one wave covers 4.0 divisions and the peaks are 2.0 divisions high. In trace B, one wave covers 2.0 divisions and the peaks are 3.0 divisions high. Compare the notes.

Trace A: T=4.0×2=8.0T = 4.0 \times 2 = 8.0 ms, so f=10.0080=125f = \dfrac{1}{0.0080} = 125 Hz. Peak p.d. =2.0×10=20= 2.0 \times 10 = 20 mV.

Trace B: T=2.0×2=4.0T = 2.0 \times 2 = 4.0 ms, so f=10.0040=250f = \dfrac{1}{0.0040} = 250 Hz. Peak p.d. =3.0×10=30= 3.0 \times 10 = 30 mV.

Answer: note B has twice the frequency of note A, so it sounds higher. Its peaks are 1.5 times as tall, so it is louder as well.

How do you choose good settings?

If dozens of waves are crammed together, you cannot count them, so choose less time per division. If less than one complete wave fits on the screen, choose more time per division. Aim for a few complete waves across the screen.

If the peaks run off the top and bottom of the screen, choose more volts per division. If the trace is nearly flat, choose fewer volts per division. A large trace that still fits on the screen is the easiest to read accurately.

In our sound waves and oscilloscope simulation, the starting set-up plays 500 Hz, with the timebase at 0.5 ms/div and the Y-gain at 2 mV/div. Press Play and wait for the sound to reach the microphone. Count the divisions for one complete wave, work out the frequency, then check your answer in the Reading the trace box. Next, change the Timebase and Y-gain settings: the trace stretches or shrinks, but the note stays the same. Then pick Low hum or Whistle from the Set-ups menu and read the new trace.

Common mistakes

  • Treating the trace as a picture of the wave. It is a graph of p.d. against time. Air moves back and forth along the sound's path, not across it.
  • Forgetting to convert ms or µs into seconds. With T = 2.5 ms, the frequency is 400 Hz. Writing 1÷2.5=0.41 \div 2.5 = 0.4 Hz is a units slip.
  • Counting half a wave. From a peak to the next trough is only half a period.
  • Measuring height from the wrong place. Peak p.d. is measured from the centre line, not from the bottom of the screen or from a trough.
  • Comparing traces drawn with different settings. Check that the timebase and Y-gain match first.
  • Mixing up the two controls. The timebase works across (time). The Y-gain works up and down (p.d.).

Key points

  • An oscilloscope trace is a graph of p.d. against time, not a picture of the wave.
  • Period = divisions for one complete wave × timebase. Then f=1/Tf = 1/T, with T in seconds.
  • Peak p.d. = divisions from the centre line to a peak × Y-gain.
  • With the same settings, more waves on the screen means a higher pitch, and taller peaks mean a louder sound.