Skip to content

Atomic and nuclear physics simulation

Radioactive Decay and Half-Life Simulation

A tray of glowing nuclei that decay at random, a GM tube that clicks as it counts, and a live graph with a draggable half-life line. Compare small and large samples, correct count rates for background, and run eight real isotopes from radon-220 to carbon-14.

Loading simulation…
Show symbols for

Predict first

Question 1 of 4

A sample of 1600 iodine-131 nuclei has a half-life of about 8 days. Roughly how many of them are still undecayed after 4 half-lives (about 32 days)?

Try this

  1. 1Press Play and watch the protactinium-234m nuclei. When the staircase on the graph crosses the dashed line at ½, note the time printed under the graph. Then press ¼ under Half-life line at. Is the new time about double the first?
  2. 2Switch on Mark every halving and look at the brackets along the time axis. Does each halving of this sample take roughly the same time?
  3. 3Choose 100 under Nuclei at the start and press Play, then press New sample and Play again a few times. How far does the staircase stray from the theory curve? Repeat with 1600 nuclei.
  4. 4Choose 1600 under Nuclei at the start, open Count rate, raise the Background count rate to 1.5 counts/s and press Play. When the run ends, switch off Subtract the background. How much longer does the count rate seem to take to halve?
  5. 5In Choose an isotope for the job, pick Paper gauge and try all three isotopes before pressing Show the usual choice. Which property rules each wrong one out?

A tray of unstable nuclei

The stage shows a sample as a square tray of 100, 400 or 1600 nuclei. Every glowing dot is a parent nucleus that has not decayed yet. In each tiny time step, each one has the same small chance of decaying, fixed by the isotope. When one goes, it flashes, sends out its radiation (orange alpha streaks, blue beta tracks or green gamma ripples, coloured as in the alpha, beta and gamma simulation) and dims to the daughter colour. Nothing about a nucleus warns you that it is next. The sample number makes the randomness repeatable: Reset replays exactly the same decays, while New sample deals a fresh set.

The staircase and the half-life line

The main graph plots the number of undecayed nuclei against time. Because nuclei decay one at a time, the line drops in small steps and wanders either side of the dashed theory curve, N=N0(12)t/T1/2N = N_0 \left(\tfrac{1}{2}\right)^{t/T_{1/2}}. Drag the orange line, or press its buttons, to set it at a half, a quarter, an eighth or a sixteenth of the starting number, and the time at which this sample first sank that low appears under the graph. Mark every halving adds a diamond at each halving and a bracket showing how long it took. The brackets come out roughly equal, and that is the whole idea of a half-life: the same fraction goes in each equal stretch of time, however many nuclei remain.

Small samples, big scatter

With 100 nuclei the brackets can differ by a quarter or more; with 1600 they agree far better. The scatter only grows as the square root of how many nuclei there are, so the relative wobble shrinks as samples grow. Real samples hold billions upon billions of nuclei, which is why measured decay curves look so smooth.

Counting with a GM tube

A Geiger–Müller tube beside the tray records a share of the decays, set by its efficiency. Its counter ticks and its lamp flashes for each one it catches. The Activity graph shows every decay in each counting interval, while Count rate shows only the recorded ones, so it sits lower. For the two lab isotopes, protactinium-234m and radon-220, and for a custom isotope, the tube also picks up background radiation at a rate you choose. Background does not decay, so the readings level off at it instead of falling towards zero. Halving uncorrected readings therefore gives a time that is too long, and subtracting the background from each reading first brings back the true half-life. A smooth best-fit curve through the points keeps the reading steady despite the noise.

Real isotopes on a time-lapse

Every run lasts roughly half a minute on screen, so the time axis is stretched or squeezed to suit the isotope, and the note under the menu states the scale: one second on screen is 15 s of protactinium time but 1250 years of carbon-14 time. The half-lives are rounded measured values, from 55.6 s for radon-220 to 5700 years for carbon-14. Each decay equation in the panel balances, with the mass numbers and the atomic numbers adding up on both sides.

Choosing an isotope for a job

The Choose an isotope for the job panel sets five jobs, from a smoke alarm to radiotherapy. Pick an isotope for each and the feedback explains, through its radiation and its half-life, why it would or would not do the job.

Check your understanding

8 questions

  1. 1.A sample starts with 2400 undecayed nuclei. About how many are still undecayed after 3 half-lives?
  2. 2.Protactinium-234m decays by giving out beta particles. What happens to each nucleus that decays?
  3. 3.Why does a GM tube record a lower count rate than the activity of the source?
  4. 4.A corrected count rate falls from 480 to 60 counts/min in 45 minutes. What is the half-life?
  5. 5.Readings of a decaying source include background radiation that has not been subtracted. What happens to the half-life found from them?
  6. 6.Which of these changes the half-life of a sample of iodine-131?
  7. 7.After 5 half-lives, what is the ratio of the activity now to the activity at the start?
  8. 8.Why is technetium-99m a good choice of tracer for a medical scan?

For teachers

Embed it in your site or open it full-screen for the projector.

Read more