Physics only: spec points 4.4.3.1 to 4.4.3.3
This page is GCSE Physics only, on both tiers; Combined Science papers leave it out. There is no equation. Aim to be able to:
- list where background radiation comes from, and say why a job or a home town can raise a person's dose
- handle doses in sieverts (questions give the unit), with 1 Sv = 1000 mSv
- explain how half-life affects the hazard from a radioactive material
- describe how hospitals use radiation to see inside the body and to kill or shrink unwanted tissue, and weigh each use against its risks using data
Contamination and irradiation (4.4.2.4), summarised below, are for all students.
Background radiation
Low levels of radiation reach us constantly, wherever we are: this is background radiation.
- Natural: rocks and soil, including radon gas seeping from the ground; cosmic rays from space; traces of radioactive isotopes in food and in our bodies.
- Man-made: dust from nuclear bomb tests and material released by accidents such as Chernobyl in 1986. (Medical X-rays also add to a person's yearly dose, but AQA's examples of man-made background are fallout and accidents.)
Location and occupation both matter. Homes on granite, as in parts of Cornwall, collect more radon. Airline crews spend long hours high up, where cosmic rays are stronger. Hospital and nuclear workers wear badges that record their dose.
Radiation dose describes the risk of harm from the radiation a body absorbs. Its unit is the sievert (Sv), and everyday doses are quoted in millisieverts: 1 mSv = 0.001 Sv.
Worked example: correcting for background
With no source nearby, a GM tube records 63 counts in 3 minutes. With a source in place, it records 1530 counts in 5 minutes.
- Background count rate: counts per minute.
- Count rate with the source: counts per minute.
- Corrected count rate: counts per minute, or counts per second.
Half-life and hazard
Half-lives vary enormously: about 6 hours for technetium-99m, 8 days for iodine-131, 5.3 years for cobalt-60 and 4.5 billion years for uranium-238.
- Short half-life: for the same number of unstable nuclei, activity is higher and the danger intense, but brief: two days after a technetium-99m scan, under 1% of the activity remains.
- Long half-life: activity is lower but can last for thousands of years or more, so nuclear waste stays hazardous for generations.
Radiation in medicine
| Use | How it works | Why this choice |
|---|---|---|
| Looking inside the body | A tracer such as technetium-99m is injected; a gamma camera outside the body maps where it collects. | Gamma escapes the body and ionises weakly. A half-life of hours covers the scan, then fades. |
| Destroying a tumour from outside | Narrow gamma beams aimed from several directions cross at the tumour. | The tumour gets a large dose; healthy tissue on each path gets much less. |
| Treating tissue from inside | Swallowed iodine-131 gathers in the thyroid gland. | Its beta particles travel only a short way through tissue, so the damage stays local. |
Ionising radiation can damage cells and cause cancer, so each use is a balance: a scan adds a small dose, but early diagnosis saves lives. Judge risk from data, not fear.
Contamination or irradiation?
Irradiation: an object sits in the path of radiation from a source outside it. It stops when the source is removed or blocked, and the object does not become radioactive: gamma-sterilised syringes are safe. Contamination: radioactive atoms have ended up on or inside something where they are not wanted, and they keep decaying until removed. Swallowed or breathed in, an alpha emitter is the most dangerous; outside the body, skin absorbs alpha.
In the simulation above
- Choose None under Source and press Play. With the holder empty, the rate settles near 20 counts/min: the Background count rate setting.
- Choose Gamma and press Skip: about 1220 counts/min. Subtract the background, then compare with the Corrected count rate card, about 1200.
- Choose Lead under Absorber and count again. Its starting 2 cm cuts the rate to about 400 counts/min: shielding at work.
- Open Range, keep Gamma, set Tube distance from the source to 6 cm and count. The corrected rate falls to about 320 counts/min: distance protects too.