What AQA asks for: spec point 4.3.2.3
Specific latent heat belongs to the internal energy part of the particle model topic. All AQA students need it: Foundation and Higher candidates, whether they take GCSE Physics or Combined Science. Its equation is given on the Physics equation sheet, so you must recognise when to use it, not memorise it. You should be able to:
- explain why the temperature stays the same during a change of state, even though the internal energy changes
- define specific latent heat, and tell fusion apart from vaporisation
- calculate with , rearranging it when needed
- read temperature–time graphs for heating and cooling, including the flat sections where the state changes
- choose between specific latent heat and specific heat capacity
The specification also lists an experiment to measure the specific latent heat of fusion of ice as a suggested activity. It is not one of the required practicals.
The equation
is the energy for the change of state (J), the mass (kg) and the specific latent heat (J/kg).
The specific latent heat is the energy needed to turn 1 kg of a substance from one state into another while its temperature stays the same. Each substance has two values:
- Specific latent heat of fusion: solid to liquid. Freezing releases the same energy. For water, about 3.34 × 10⁵ J/kg.
- Specific latent heat of vaporisation: liquid to vapour. Condensing releases the same energy. For water, about 2.26 × 10⁶ J/kg.
Vaporising water takes nearly seven times as much energy per kilogram as melting it, because the particles must be separated completely, not just freed from a fixed pattern.
Worked example 1: reading a flat section. A 150 W heater sits in 0.16 kg of crushed ice already at 0 °C. The temperature–time graph stays flat for 6.0 minutes. Assuming all of the energy melts ice, find the specific latent heat of fusion.
Energy: from , which you must recall, J. Equation: . Substitution: . Answer: J/kg, about 3.4 × 10⁵ J/kg (2 s.f.).
Worked example 2: water into ice. A freezer turns 0.30 kg of water at 15 °C into ice at 0 °C. How much energy must it remove? Use J/kg °C and J/kg.
Cooling to 0 °C: J. Freezing: J. Answer: total J, about 1.19 × 10⁵ J (3 s.f.). Over four-fifths of it is latent heat.
Heating and cooling graphs
On a temperature–time graph for steady heating, sloping sections show one state changing temperature (). Flat sections show two states together at the melting or boiling point ().
On a flat section the internal energy rises but the temperature does not. The energy raises the potential energy of the particles as the forces between them are overcome; their average kinetic energy stays the same. With steady power and no losses, a flat section lasts .
On a cooling curve, a freezing liquid keeps losing energy to the surroundings, but freezing releases latent heat at the same rate, so the line stays flat until no liquid is left.
Using the simulation
In the simulation above, Heating curve heats 0.50 kg of ice from −20 °C with 500 W and Lagged insulation. The heater starts on, so press Play: the graph goes flat at 0 °C and at 100 °C (standard atmospheric pressure is assumed). Stage by stage gives = 1.67 × 10⁵ J for melting and = 1.13 × 10⁶ J for boiling.
Set Insulation to No losses, which restarts the run, and press Play again. After melting, the panel shows the joulemeter at 21000 J at 42.0 s and 188000 J at 376.0 s, so = 167000 J ÷ 0.50 kg = 3.34 × 10⁵ J/kg. Boiling gives 1130000 J ÷ 0.50 kg = 2.26 × 10⁶ J/kg. With Lagged or None, melting comes out low (the room helps to melt the ice) and boiling high (the heater also replaces energy lost to the room).
Then pick Melting practical (50 W, 5 min timer, Realistic losses) and press Play. When the run ends at 420 s, From the first and last readings under Readings gives 3.51 × 10⁵ J/kg With the control and 2.99 × 10⁵ J/kg Without the control.